APPROVED DOCUMENT K

 0    58 fiche    sim
laste ned mp3 Skriv ut spille sjekk deg selv
 
spørsmålet svaret
approved
What is a approved Document?
begynn å lære
zatwierdzony
Building Regulations
begynn å lære
Przepisy budowlane
protection from impact
Protection from falling, collision and impact
begynn å lære
Ochrona przed uderzeniami
impact
The definition of impact is one thing crashing into or having an affect on another.
begynn å lære
wpływ / zderzenie
ladder
begynn å lære
drabina
loading bays
begynn å lære
strefa załadunku
Vehicle barriers
begynn å lære
Bariery pojazdów
glazing
begynn å lære
szyby
provisions
Additional provisions for glazing in buildings other than dwellings.
begynn å lære
Przepisy
dwellings
Additional provisions for glazing in buildings other than dwellings.
begynn å lære
mieszkaniowe
trapping by doors
trap.
begynn å lære
uwięzienie przez drzwi
pułapka
compliance with the law
begynn å lære
zgodność z prawem
workmanship
begynn å lære
jakość wykonania
Handrail
begynn å lære
Poręcz
helical stair
helical stair = spiral stair
begynn å lære
spiralny schody
noising
begynn å lære
nosek schodów
stair tread
begynn å lære
stopnica
pitch
begynn å lære
kąt nachylenia
rise
begynn å lære
wysokość stopnia
riser
begynn å lære
wysokość stopnia
landing
The width and length of every landing should be at least as great as the smallest width of the flight. (minimum 1 m)
begynn å lære
podest / spocznik
staircase
begynn å lære
klatka schodowa
stair enclosure
begynn å lære
klatka schodowa
flight of stairs
begynn å lære
bieg schodów
straight flight stairs
begynn å lære
Schody jednobiegowe proste
dog-legged stairs
begynn å lære
Schody dwubiegunowe proste
winding stairs
begynn å lære
kręte schody
cantiliver stairs
begynn å lære
schody wspornikowe
timber stairs
begynn å lære
Schody z drewna
going
going = tread
begynn å lære
stopnica
RISER in PRIVATE STAIRS
Rise maximum 220mm. RISE = 150mm- 220mm.
begynn å lære
wysokość stopnia
H = 150mm-220mm
GOING in PRIVATE STAIRS
GOING minimum 220mm. GOING = 220mm- 300mm.
begynn å lære
SZEROKOŚĆ STOPNIA
intended
Private: intended to be used for only one dwelling.
begynn å lære
przeznaczony
assembly
Institutional and assembly: Serving a place where many people gather.
begynn å lære
zgromadzenie
gather
Institutional and assembly: Serving a place where many people gather.
begynn å lære
zbierać
headroom
Minimum headroom= 2m.
begynn å lære
wysokość prześwitu
Institutional and assembly stairs
Maximum rise = 180mm. Minimum going 280.(If the area of a floor of the building is less than 100m2, the going may be reduced to 250mm.)
begynn å lære
Instytucjonalne i zbiorowe schody
Pitch
the maximum pitch for private stair is 42°.
begynn å lære
kąt nachylenia
gangway for seated spectators
The maximum pitch for gangways for seated spectators is 35°.
begynn å lære
Przejście na siedzących widzów
escalator
begynn å lære
schody ruchome
stair well
begynn å lære
dusza schodów
fire escape stairs
begynn å lære
schody ewakuacyjne
dividing flights
A stair in a public building which is wider than 1800mm should be divided into flights which are not wider than 1800mm.
begynn å lære
podzielenie biegu
length of flights
The number of risers in a flight should be limited to 16 if a stair serves an area used as a shop or for assembly purposes.
begynn å lære
długość biegu
lending next to doors
at least 400mm.
begynn å lære
spocznik obok drzwi
cupboard
at least 400mm.
begynn å lære
szafka nad spocznikiem
alternating tread stair
begynn å lære
zmienny stopień
walkways
begynn å lære
chodniki
Handrails for stairs
In all buildings hadrail height should be between 900mm and 1000mm measured to the top of the handrail from the pitch line or floor.
begynn å lære
Poręcze na schodach
guarding
Flights and landings shoul be guarded at the sides (in dewellings) when there is a drop of more than 600mm.
begynn å lære
osłona / ochrona
drop
begynn å lære
spadek
guarding
Single family dwellings:1. Stairs, landings, ramps, edges of internal floors. H= 900mm. 2. External balconies and edges of roof. H= 1100mm.
begynn å lære
osłona / ochrona
suitable handrails for common stairs
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
begynn å lære
odpowiednie porecze dla powszechnych schodów poręcze
formula
The normal relationship between the dimensions of the rise and going is that twice the rise plus the going (2R+G) should be between 550mm and 700mm.
begynn å lære
wzór
2R+G = 550mm -700mm
readily
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
begynn å lære
łatwo
Utility stair
begynn å lære
schody użyteczności publicznej
external stairs
For dwellings, for external tapered stairs that are part of the buildings, the going should be a minimum of 280mm.
begynn å lære
schody zewnętrzne
Width of STAIRS
minimum width of 900mm. Landings should be at least the width and length of the minimum width of the fight. For buildings other than dwellings, each landing should have an unobstructed length of at least 1,200m.
begynn å lære
Szerokość schodów